visit the hl7 website The Demo site for our new HL7 Version 2+ (plus) Standard

ECD - Equipment Command Segment (ECD)

Global Profile (Differential)
Seq#Data ElementDescriptionFlagsImplementVocabulary
ECD
101390Reference Command Number
=

Truncation not allowed!

SHALL
201391Remote Control Command SHALLrepr: RemoteControlCommand (CD) hl7VS-remoteControlCommand (VS) remoteControlCommand (CS)
Global Profile (Snapshot)
Seq#Data ElementDescriptionFlagsImplementCardinalityVocabularyData Type
ECD
101390Reference Command Number
=

Truncation not allowed!

SHALL[1..1]
NM

Numeric

201391Remote Control Command SHALL[1..1]repr: RemoteControlCommand (CD) hl7VS-remoteControlCommand (VS) remoteControlCommand (CS)
CWE

Coded with Exceptions

301392Response Required MAY[0..1]univ: Yes/noIndicator (CD) hl7VS-yes-no-Indicator (VS) expandedYes-NoIndicator (CS)
ID

Coded Value for HL7 Defined Tables

401393Requested Completion Time
W

withdrawn Element

SHOULD NOT  
501394Parameters MAY[0..*]
TX

Text Data