This page is part of the EU Manifest-based Access to DICOM Objects (EU-MADO) (v1.0.0-ballot: STU 1 Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

: MADO EU Web Viewer Endpoint

Raw json | Download

{
  "resourceType" : "Endpoint",
  "id" : "endpoint-webviewer",
  "meta" : {
    "profile" : [
      🔗 "http://hl7.eu/fhir/imaging-manifest/StructureDefinition/EuMadoWebViewerEndpoint"
    ]
  },
  "language" : "en",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: Endpoint endpoint-webviewer</b></p><a name=\"endpoint-webviewer\"> </a><a name=\"hcendpoint-webviewer\"> </a><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\"/><p style=\"margin-bottom: 0px\">Profile: <a href=\"StructureDefinition-EuMadoWebViewerEndpoint.html\">EU MADO Web Viewer Endpoint</a></p></div><p style=\"border: 1px #661aff solid; background-color: #e6e6ff; padding: 10px;\">Unnamed Endpoint (DICOM web viewer for the study (MADO Endpoint Connection Types Code System#web-viewer)): https://example.org/viewer?study=1.3.6.1.4.1.99999.1.2.1.101</p><hr/><table class=\"grid\"><tr><td style=\"background-color: #f3f5da\" title=\"The status of the endpoint\">Status:</td><td colspan=\"3\">Active</td></tr><tr><td style=\"background-color: #f3f5da\" title=\"The technical base address for connecting to this endpoint\">Address:</td><td colspan=\"3\"><a href=\"https://example.org/viewer?study=1.3.6.1.4.1.99999.1.2.1.101\">https://example.org/viewer?study=1.3.6.1.4.1.99999.1.2.1.101</a></td></tr><tr><td style=\"background-color: #f3f5da\" title=\"The protocol, profile or standard used to connect to the endpoint\">Connection Type:</td><td colspan=\"3\"><a href=\"https://profiles.ihe.net/RAD/MADO/1.0.0/CodeSystem-MadoEndpointConnectionTypes.html#MadoEndpointConnectionTypes-web-viewer\">MADO Endpoint Connection Types Code System: web-viewer</a> (DICOM web viewer for the study)</td></tr><tr><td style=\"background-color: #f3f5da\" title=\"The type of content that may be used at this endpoint\">Payload Type:</td><td colspan=\"3\"><span title=\"Codes:{http://terminology.hl7.org/CodeSystem/endpoint-payload-type none}\">None</span></td></tr><tr><td style=\"background-color: #f3f5da\" title=\"The mime types that can be sent to and/or received from the endpoint\">Mime Type:</td><td colspan=\"3\">text/html</td></tr></table></div>"
  },
  "status" : "active",
  "connectionType" : {
    "system" : "https://profiles.ihe.net/RAD/MADO/CodeSystem/MadoEndpointConnectionTypes",
    "code" : "web-viewer"
  },
  "payloadType" : [
    {
      "coding" : [
        {
          "system" : "http://terminology.hl7.org/CodeSystem/endpoint-payload-type",
          "code" : "none"
        }
      ]
    }
  ],
  "payloadMimeType" : [
    "text/html"
  ],
  "address" : "https://example.org/viewer?study=1.3.6.1.4.1.99999.1.2.1.101"
}