Profile Comparison between http://hl7.eu/fhir/laboratory/StructureDefinition/Ratio-eu-lab vs http://hl7.eu/fhir/laboratory/StructureDefinition/Ratio-eu-lab

Left:Ratio (Eu Lab) (http://hl7.eu/fhir/laboratory/StructureDefinition/Ratio-eu-lab)
Right:Ratio (Eu Lab) (http://hl7.eu/fhir/laboratory/StructureDefinition/Ratio-eu-lab)

Messages

ErrorStructureDefinition.versionValues for version differ: '0.1.0' vs '0.1.1'
InformationStructureDefinition.dateValues for date differ: '2024-02-20T12:32:58+01:00' vs '2025-03-25T12:00:10+01:00'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/uv/ips/StructureDefinition/Ratio-uv-ips
      .copyrightUsed by permission of HL7 Europe, all rights reserved Creative Commons License
        .date2024-02-20T12:32:58+01:002025-03-25T12:00:10+01:00
        • Values Differ
        .descriptionThis profile constrains the Ratio data type to use UCUM as the code system for units and optionally share measurement uncertainty
          .experimental
            .fhirVersion4.0.1
              .jurisdiction
                ..jurisdiction[0]http://unstats.un.org/unsd/methods/m49/m49.htm#150
                  .kindcomplex-type
                    .nameRatioEuLab
                      .publisherHL7 Europe
                        .purposeThis profile of the Ratio data type imposes the usage of the UCUM as the code system for units and allows expressing uncertainty of measurement
                          .statusactive
                            .titleRatio (Eu Lab)
                              .typeRatio
                                .urlhttp://hl7.eu/fhir/laboratory/StructureDefinition/Ratio-eu-lab
                                  .version0.1.00.1.1
                                  • Values Differ

                                  Structure

                                  NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.R TypeR Description & ConstraintsCommentsdoco
                                  .. Ratio C0..*RatioIPSA measured ratio using UCUM
                                  rat-1: Numerator and denominator SHALL both be present, or both are absent. If both are absent, there SHALL be some extension present
                                  C0..*RatioIPSA measured ratio using UCUM
                                  rat-1: Numerator and denominator SHALL both be present, or both are absent. If both are absent, there SHALL be some extension present
                                    ... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                      ... Slices for extension 0..*ExtensionAdditional content defined by implementations
                                      Slice: Unordered, Open by value:url
                                      0..*ExtensionAdditional content defined by implementations
                                      Slice: Unordered, Open by value:url
                                        ... numerator SC0..1??A measured amount using UCUM
                                        qty-3: If a code for the unit is present, the system SHALL also be present
                                        SC0..1??A measured amount using UCUM
                                        qty-3: If a code for the unit is present, the system SHALL also be present

                                          doco Documentation for this format