HL7 Europe Imaging Study Report
0.1.0-ballot - ci-build 150

This page is part of the HL7 Europe Imaging Study Report (v0.1.0-ballot: STU 1 Ballot 1) based on FHIR (HL7® FHIR® Standard) v5.0.0. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

Data Type Profile: Report obligations for EuQuantity

Official URL: http://hl7.eu/fhir/imaging-r5/StructureDefinition/Report-EuQuantity Version: 0.1.0-ballot
Draft as of 2025-05-14 Computable Name: Report_EuQuantity

Copyright/Legal: Used by permission of HL7 Europe, all rights reserved Creative Commons License

Report obligations for EuQuantity

Usage:

  • This DataType Constraint is not used by any profiles in this Implementation Guide

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity C 0..* QuantityEu A measured or measurable amount
ele-1: All FHIR elements must have a @value or children
qty-3: If a code for the unit is present, the system SHALL also be present
... Slices for extension Content/Rules for all slices
.... extension:uncertainty O 0..1 decimal Standard Deviation (same units as the quantity)
URL: http://hl7.org/fhir/StructureDefinition/iso21090-uncertainty
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
ObligationsActor
SHALL:populate-if-known Imaging study report provider
.... extension:uncertaintyType O 0..1 code Probability Distribution Type for uncertainty
URL: http://hl7.org/fhir/StructureDefinition/iso21090-uncertaintyType
Binding: ProbabilityDistributionType (required)
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
ObligationsActor
SHALL:populate-if-known Imaging study report provider
... comparator ?!Σ 0..1 code < | <= | >= | > | ad - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.


ele-1: All FHIR elements must have a @value or children
... unit OΣ 0..1 string Unit representation
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known Imaging study report provider
... code OΣC 0..1 code Coded form of the unit
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known Imaging study report provider

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Quantity.comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
qty-3errorQuantityIf a code for the unit is present, the system SHALL also be present
: code.empty() or system.exists()

This structure is derived from QuantityEu

NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity 0..* QuantityEu A measured or measurable amount
... Slices for extension Content/Rules for all slices
.... extension:uncertainty O 0..1 Uncertainty(5.2.0) Standard Deviation (same units as the quantity)
ObligationsActor
SHALL:populate-if-known Imaging study report provider
.... extension:uncertaintyType O 0..1 UncertaintyType(5.2.0) Probability Distribution Type for uncertainty
ObligationsActor
SHALL:populate-if-known Imaging study report provider
... unit O 0..1 string Unit representation
ObligationsActor
SHALL:populate-if-known Imaging study report provider
... system O 0..1 uri System that defines coded unit form
ObligationsActor
SHALL:populate-if-known Imaging study report provider

doco Documentation for this format
NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity C 0..* QuantityEu A measured or measurable amount
qty-3: If a code for the unit is present, the system SHALL also be present
... id 0..1 id Unique id for inter-element referencing
... Slices for extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... extension:uncertainty O 0..1 decimal Standard Deviation (same units as the quantity)
URL: http://hl7.org/fhir/StructureDefinition/iso21090-uncertainty
ObligationsActor
SHALL:populate-if-known Imaging study report provider
.... extension:uncertaintyType O 0..1 code Probability Distribution Type for uncertainty
URL: http://hl7.org/fhir/StructureDefinition/iso21090-uncertaintyType
Binding: ProbabilityDistributionType (required)
ObligationsActor
SHALL:populate-if-known Imaging study report provider
... value Σ 0..1 decimal Numerical value (with implicit precision)
... unit OΣ 0..1 string Unit representation
ObligationsActor
SHALL:populate-if-known Imaging study report provider
... system OΣC 0..1 uri System that defines coded unit form
ObligationsActor
SHALL:populate-if-known Imaging study report provider
... code OΣC 0..1 code Coded form of the unit
ObligationsActor
SHALL:populate-if-known Imaging study report provider

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Quantity.comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
qty-3errorQuantityIf a code for the unit is present, the system SHALL also be present
: code.empty() or system.exists()

This structure is derived from QuantityEu

Summary

Key Elements View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity C 0..* QuantityEu A measured or measurable amount
ele-1: All FHIR elements must have a @value or children
qty-3: If a code for the unit is present, the system SHALL also be present
... Slices for extension Content/Rules for all slices
.... extension:uncertainty O 0..1 decimal Standard Deviation (same units as the quantity)
URL: http://hl7.org/fhir/StructureDefinition/iso21090-uncertainty
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
ObligationsActor
SHALL:populate-if-known Imaging study report provider
.... extension:uncertaintyType O 0..1 code Probability Distribution Type for uncertainty
URL: http://hl7.org/fhir/StructureDefinition/iso21090-uncertaintyType
Binding: ProbabilityDistributionType (required)
ele-1: All FHIR elements must have a @value or children
ext-1: Must have either extensions or value[x], not both
ObligationsActor
SHALL:populate-if-known Imaging study report provider
... comparator ?!Σ 0..1 code < | <= | >= | > | ad - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.


ele-1: All FHIR elements must have a @value or children
... unit OΣ 0..1 string Unit representation
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known Imaging study report provider
... code OΣC 0..1 code Coded form of the unit
ele-1: All FHIR elements must have a @value or children
ObligationsActor
SHALL:populate-if-known Imaging study report provider

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Quantity.comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
qty-3errorQuantityIf a code for the unit is present, the system SHALL also be present
: code.empty() or system.exists()

Differential View

This structure is derived from QuantityEu

NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity 0..* QuantityEu A measured or measurable amount
... Slices for extension Content/Rules for all slices
.... extension:uncertainty O 0..1 Uncertainty(5.2.0) Standard Deviation (same units as the quantity)
ObligationsActor
SHALL:populate-if-known Imaging study report provider
.... extension:uncertaintyType O 0..1 UncertaintyType(5.2.0) Probability Distribution Type for uncertainty
ObligationsActor
SHALL:populate-if-known Imaging study report provider
... unit O 0..1 string Unit representation
ObligationsActor
SHALL:populate-if-known Imaging study report provider
... system O 0..1 uri System that defines coded unit form
ObligationsActor
SHALL:populate-if-known Imaging study report provider

doco Documentation for this format

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity C 0..* QuantityEu A measured or measurable amount
qty-3: If a code for the unit is present, the system SHALL also be present
... id 0..1 id Unique id for inter-element referencing
... Slices for extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
.... extension:uncertainty O 0..1 decimal Standard Deviation (same units as the quantity)
URL: http://hl7.org/fhir/StructureDefinition/iso21090-uncertainty
ObligationsActor
SHALL:populate-if-known Imaging study report provider
.... extension:uncertaintyType O 0..1 code Probability Distribution Type for uncertainty
URL: http://hl7.org/fhir/StructureDefinition/iso21090-uncertaintyType
Binding: ProbabilityDistributionType (required)
ObligationsActor
SHALL:populate-if-known Imaging study report provider
... value Σ 0..1 decimal Numerical value (with implicit precision)
... unit OΣ 0..1 string Unit representation
ObligationsActor
SHALL:populate-if-known Imaging study report provider
... system OΣC 0..1 uri System that defines coded unit form
ObligationsActor
SHALL:populate-if-known Imaging study report provider
... code OΣC 0..1 code Coded form of the unit
ObligationsActor
SHALL:populate-if-known Imaging study report provider

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Quantity.comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|5.0.0
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
qty-3errorQuantityIf a code for the unit is present, the system SHALL also be present
: code.empty() or system.exists()

This structure is derived from QuantityEu

Summary

 

Other representations of profile: CSV, Excel, Schematron