V2+
2.1.0 - CI Build
V2+ - Local Development build (v2.1.0). See the Directory of published versions
XML representation of the OM2 logical model.
<StructureDefinition xmlns="http://hl7.org/fhir">
<id value="OM2"/>
<meta>
<lastUpdated value="2021-04-23T16:53:24.250+02:00"/>
</meta>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml">Segment: OM2</div>
</text>
<url value="http://hl7.org/fhir/v2plus/StructureDefinition/OM2"/>
<version value="2.1.0"/>
<name value="OM2"/>
<title value="Segment: OM2"/>
<status value="draft"/>
<experimental value="true"/>
<date value="2021-04-23T16:53:24+02:00"/>
<publisher value="Frank Oemig"/>
<description value="Numeric Observation"/>
<copyright value="FO"/>
<fhirVersion value="4.0.1"/>
<kind value="logical"/>
<abstract value="false"/>
<type value="OM2"/>
<baseDefinition value="http://hl7.org/fhir/StructureDefinition/Base"/>
<derivation value="specialization"/>
<snapshot>
<element id="OM2">
<path value="OM2"/>
<definition value="Numeric Observation"/>
<min value="1"/>
<max value="1"/>
<base>
<path value="Base"/>
<min value="0"/>
<max value="*"/>
</base>
<isModifier value="false"/>
</element>
<element id="OM2.SequenceNumber-TestObservationMasterFile">
<path value="OM2.SequenceNumber-TestObservationMasterFile"/>
<short value="SequenceNumber-TestObservationMasterFile"/>
<definition
value="Attribute: Sequence Number - TestObservation Master File"/>
<min value="0"/>
<max value="1"/>
<base>
<path value="OM2.SequenceNumber-TestObservationMasterFile"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="NM"/>
</type>
</element>
<element id="OM2.UnitsofMeasure">
<path value="OM2.UnitsofMeasure"/>
<short value="UnitsofMeasure"/>
<definition value="Attribute: Units of Measure"/>
<min value="0"/>
<max value="1"/>
<base>
<path value="OM2.UnitsofMeasure"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="CWE"/>
</type>
</element>
<element id="OM2.RangeofDecimalPrecision">
<path value="OM2.RangeofDecimalPrecision"/>
<short value="RangeofDecimalPrecision"/>
<definition value="Attribute: Range of Decimal Precision"/>
<min value="0"/>
<max value="*"/>
<base>
<path value="OM2.RangeofDecimalPrecision"/>
<min value="0"/>
<max value="*"/>
</base>
<type>
<code value="NM"/>
</type>
</element>
<element id="OM2.CorrespondingSIUnitsofMeasure">
<path value="OM2.CorrespondingSIUnitsofMeasure"/>
<short value="CorrespondingSIUnitsofMeasure"/>
<definition value="Attribute: Corresponding SI Units of Measure"/>
<min value="0"/>
<max value="1"/>
<base>
<path value="OM2.CorrespondingSIUnitsofMeasure"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="CWE"/>
</type>
</element>
<element id="OM2.SIConversionFactor">
<path value="OM2.SIConversionFactor"/>
<short value="SIConversionFactor"/>
<definition value="Attribute: SI Conversion Factor"/>
<min value="0"/>
<max value="1"/>
<base>
<path value="OM2.SIConversionFactor"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="TX"/>
</type>
</element>
<element id="OM2.ReferenceNormalRangeforOrdinalandContinuousObservations">
<path value="OM2.ReferenceNormalRangeforOrdinalandContinuousObservations"/>
<short value="ReferenceNormalRangeforOrdinalandContinuousObservations"/>
<definition
value="Attribute: Reference (Normal) Range for Ordinal and Continuous Observations"/>
<min value="0"/>
<max value="*"/>
<base>
<path
value="OM2.ReferenceNormalRangeforOrdinalandContinuousObservations"/>
<min value="0"/>
<max value="*"/>
</base>
<type>
<code value="RFR"/>
</type>
</element>
<element id="OM2.CriticalRangeforOrdinalandContinuousObservations">
<path value="OM2.CriticalRangeforOrdinalandContinuousObservations"/>
<short value="CriticalRangeforOrdinalandContinuousObservations"/>
<definition
value="Attribute: Critical Range for Ordinal and Continuous Observations"/>
<min value="0"/>
<max value="*"/>
<base>
<path value="OM2.CriticalRangeforOrdinalandContinuousObservations"/>
<min value="0"/>
<max value="*"/>
</base>
<type>
<code value="RFR"/>
</type>
</element>
<element id="OM2.AbsoluteRangeforOrdinalandContinuousObservations">
<path value="OM2.AbsoluteRangeforOrdinalandContinuousObservations"/>
<short value="AbsoluteRangeforOrdinalandContinuousObservations"/>
<definition
value="Attribute: Absolute Range for Ordinal and Continuous Observations"/>
<min value="0"/>
<max value="1"/>
<base>
<path value="OM2.AbsoluteRangeforOrdinalandContinuousObservations"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="RFR"/>
</type>
</element>
<element id="OM2.DeltaCheckCriteria">
<path value="OM2.DeltaCheckCriteria"/>
<short value="DeltaCheckCriteria"/>
<definition value="Attribute: Delta Check Criteria"/>
<min value="0"/>
<max value="*"/>
<base>
<path value="OM2.DeltaCheckCriteria"/>
<min value="0"/>
<max value="*"/>
</base>
<type>
<code value="DLT"/>
</type>
</element>
<element id="OM2.MinimumMeaningfulIncrements">
<path value="OM2.MinimumMeaningfulIncrements"/>
<short value="MinimumMeaningfulIncrements"/>
<definition value="Attribute: Minimum Meaningful Increments"/>
<min value="0"/>
<max value="1"/>
<base>
<path value="OM2.MinimumMeaningfulIncrements"/>
<min value="0"/>
<max value="1"/>
</base>
<type>
<code value="NM"/>
</type>
</element>
</snapshot>
<differential>
<element id="OM2">
<path value="OM2"/>
<definition value="Numeric Observation"/>
<min value="1"/>
<max value="1"/>
</element>
<element id="OM2.SequenceNumber-TestObservationMasterFile">
<path value="OM2.SequenceNumber-TestObservationMasterFile"/>
<short value="SequenceNumber-TestObservationMasterFile"/>
<definition
value="Attribute: Sequence Number - TestObservation Master File"/>
<min value="0"/>
<max value="1"/>
<type>
<code value="NM"/>
</type>
</element>
<element id="OM2.UnitsofMeasure">
<path value="OM2.UnitsofMeasure"/>
<short value="UnitsofMeasure"/>
<definition value="Attribute: Units of Measure"/>
<min value="0"/>
<max value="1"/>
<type>
<code value="CWE"/>
</type>
</element>
<element id="OM2.RangeofDecimalPrecision">
<path value="OM2.RangeofDecimalPrecision"/>
<short value="RangeofDecimalPrecision"/>
<definition value="Attribute: Range of Decimal Precision"/>
<min value="0"/>
<max value="*"/>
<type>
<code value="NM"/>
</type>
</element>
<element id="OM2.CorrespondingSIUnitsofMeasure">
<path value="OM2.CorrespondingSIUnitsofMeasure"/>
<short value="CorrespondingSIUnitsofMeasure"/>
<definition value="Attribute: Corresponding SI Units of Measure"/>
<min value="0"/>
<max value="1"/>
<type>
<code value="CWE"/>
</type>
</element>
<element id="OM2.SIConversionFactor">
<path value="OM2.SIConversionFactor"/>
<short value="SIConversionFactor"/>
<definition value="Attribute: SI Conversion Factor"/>
<min value="0"/>
<max value="1"/>
<type>
<code value="TX"/>
</type>
</element>
<element id="OM2.ReferenceNormalRangeforOrdinalandContinuousObservations">
<path value="OM2.ReferenceNormalRangeforOrdinalandContinuousObservations"/>
<short value="ReferenceNormalRangeforOrdinalandContinuousObservations"/>
<definition
value="Attribute: Reference (Normal) Range for Ordinal and Continuous Observations"/>
<min value="0"/>
<max value="*"/>
<type>
<code value="RFR"/>
</type>
</element>
<element id="OM2.CriticalRangeforOrdinalandContinuousObservations">
<path value="OM2.CriticalRangeforOrdinalandContinuousObservations"/>
<short value="CriticalRangeforOrdinalandContinuousObservations"/>
<definition
value="Attribute: Critical Range for Ordinal and Continuous Observations"/>
<min value="0"/>
<max value="*"/>
<type>
<code value="RFR"/>
</type>
</element>
<element id="OM2.AbsoluteRangeforOrdinalandContinuousObservations">
<path value="OM2.AbsoluteRangeforOrdinalandContinuousObservations"/>
<short value="AbsoluteRangeforOrdinalandContinuousObservations"/>
<definition
value="Attribute: Absolute Range for Ordinal and Continuous Observations"/>
<min value="0"/>
<max value="1"/>
<type>
<code value="RFR"/>
</type>
</element>
<element id="OM2.DeltaCheckCriteria">
<path value="OM2.DeltaCheckCriteria"/>
<short value="DeltaCheckCriteria"/>
<definition value="Attribute: Delta Check Criteria"/>
<min value="0"/>
<max value="*"/>
<type>
<code value="DLT"/>
</type>
</element>
<element id="OM2.MinimumMeaningfulIncrements">
<path value="OM2.MinimumMeaningfulIncrements"/>
<short value="MinimumMeaningfulIncrements"/>
<definition value="Attribute: Minimum Meaningful Increments"/>
<min value="0"/>
<max value="1"/>
<type>
<code value="NM"/>
</type>
</element>
</differential>